Reply to Reviewer btN3

Our reply to the review by Reviewer btN3.

Thank you for the careful review. Both of your points are fair, and we ran new analyses for each. Tables and details are on an anonymous page: https://memorizon-rebuttal.pages.dev/

Q1. How often does a scored chunk actually retrieve a relevant first visit? (https://memorizon-rebuttal.pages.dev/e1/)

We replayed the training sampler (380 segments, 4,000 spans per setting, ten scored chunks each) with the training retrieval score. A latent counts as relevant if it sees at least half of the chunk's view frustum (0.3 and 0.7 give the same picture).

Table 1.

max spanrelevant first visit existstop-6 contains onegiven one existsmedian age
100 s82.7%76.4%92.5%16.8 s
200 s91.0%82.6%90.7%24.5 s
400 s95.5%86.3%90.3%37.0 s

Longer spans help because more first visits are in range and the retrieved ones are older. Retrieval itself does not get better: given that a visit exists, top-6 finds it about 90% of the time at every span.

The 200 s optimum versus the 400 s explanation

We separate them in the revision. "200 s is best" is an observation of our first runs: a second, independent training of the 200 s and 400 s models flips the order (Revisit 0.388 for 200 s, 0.444 for 400 s; the same setting also moves by 0.05-0.08 between two trainings, https://memorizon-rebuttal.pages.dev/e4/), so independent runs do not support this ordering. "Saturation" is only a hypothesis, and we agree it is not established: raising the cap from 200 s to 400 s also changes the span distribution (spans <= 30 s fall from 10.2% to 5.0%; mean span roughly doubles, 106 s to 206 s). Coverage and span mix are confounded in our runs and we cannot separate them.

Bank content

The paper already tests this for the 100 s model (Table 12, Appendix C.8): with only the bank's frames replaced at inference, mid-path Revisit falls from 0.440 (retrieved top-K) to 0.207 (random frames from the same history), 0.105 (empty bank) and 0.073 (frames from another episode); Gain falls from 0.319 to 0.109, 0.019 and 0.016. We repeated it for the 200 s and 400 s models (https://memorizon-rebuttal.pages.dev/e2/; the example videos there are from the released 4-step model, not from these checkpoints). With no bank, or a bank from another video, Gain falls to about zero (200 s: 0.359 to 0.041 / -0.002; 400 s: 0.285 to 0.013 / 0.005), and random frames from the same video recover only about a third. So all three models read their retrieved content. This does not explain why 400 s is below 200 s.

Q2. Do the external comparisons hold when realized motion is matched? (https://memorizon-rebuttal.pages.dev/e3/)

We measured camera following on all five rollout seeds and added CaR. CaR follows the path as well as we do (correlation with the prescribed yaw 0.959 vs 0.955-0.958 for Memorizon); LingBot, Matrix-Game, Infinite-World, DreamX and HY-World are clearly worse (0.70-0.89). CaR's implied horizontal field of view is 60 deg, so its camera is narrower, not worse at following.

We then stratified returns by realized yaw error, with a per-video calibration that removes the field-of-view difference. Returns with error <= 10 deg, Revisit (mean over five seeds):

Table 2. Return quality by system. Revisit (mean over five seeds) and Gain over the no-bank control; best in bold.

systemReturns with yaw error ≤ 10°
RevisitGain
Memorizon (ours)
Memorizon 100 s0.4410.305
Memorizon 200 s0.4830.361
Memorizon 400 s0.4350.310
Compared systems
CaR0.4250.289
HY-World 1.5 / Matrix-Game 3.0 / Infinite-World0.329 / 0.302 / 0.2750.146 / 0.104 / 0.164
LingBot-World-v2 / DreamX-World 1.00.163 / 0.1390.006 / 0.029

Among well-aligned returns, CaR is within seed noise of our 100 s and 400 s models and about 0.06 Revisit below the 200 s model. The other systems stay far lower, but most of their returns fall in the > 25 deg bin, which is the confound you describe. Fold-back and non-fold-back returns separately give the same picture (<= 10 deg: CaR 0.423 / 0.433; Memorizon 100 s 0.442 / 0.441; 200 s 0.481 / 0.489; 400 s 0.442 / 0.409). The yaw estimate comes from phase correlation of the generated video; it sees rotation, not translation, and is not a pose estimate.

Changes to the paper

  1. The camera-following diagnostic moves from Appendix C.7 into Sec. 4.2, with five seeds and CaR.
  2. The cross-system ranking is described as indicative; the within-backbone ablations are the primary evidence for the memory claims.
  3. We no longer claim an advantage over CaR in camera following: the two follow the prescribed path equally well.
  4. Sec. 4.3 states that 200 s was best in our first runs, reports that a second training does not reproduce it, and presents saturation only as a hypothesis.

Thank you again; your comments made these claims more careful.